Fronius Symo 5.0-3-M

  • ArtikelNr.: AR592
  • Artikelgewicht: 19,90 kg
  • Lieferzeit: 4 - 14 Werktage
  • Unser Preis : 1.635,00 €
  • inkl. 20% USt., zzgl. Versand (Spedition Kleingerät)
Wird geladen ...

Kategorie:

Beschreibung

INPUT DATA Fronius Symo 5.0-3-M
Max. input current
(Idc max1 / Idc max2) 16.0 A / 16.0 A
Max. array short circuit (MPP1 / MPP2) 24.0 A / 24.0 A
Min. input voltage
(Udc min) 150 V
Feed-in start voltage
(Udc start) 200 V
Nominal input voltage (Udc,r) 595 V
Max. input voltage
(Udc max) 1,000 V
MPP voltage range
(Umpp min - Umpp max) 163 - 800 V
Number of MPP trackers 2
Number of DC connections 2 + 2
OUTPUT DATA 
AC nominal output (Pac,r) 5,000 W
Max. output power 5,000 VA
Max. output current (Iac max) 8.0 A
Grid connection (voltage range) 3~NPE 400 V / 230 V or 3~NPE 380 V / 220 V (+20 % / -30 %)
Frequency (frequncy range) 50 Hz / 60 Hz (45 - 65 Hz)
Total harmonic distortion < 3 %
Power factor (cos fac,r) 0.85 - 1 ind. / cap.
GENERAL DATA 
Dimensions
(height x width x depth) 645 x 431 x 204 mm
Weight 19.9 kg
Degree of protection IP 65
Protection class 1
Overvoltage category (DC / AC)1) 2 / 3
Night time consumption < 1 W
Inverter design Transformerless
Cooling Regulated air cooling
Installation Indoor and outdoor installation
Ambient temperature range -25°C to +60°C
Permitted humidity 0 % to 100 %
Max. altitude 2,000 m / 3,400 m (unrestricted / restricted voltage range)
DC connection technology 4x DC+ and 4x DC- screw terminals 2.5 mm² - 16 mm² 2)
AC connection technology 5-pin AC screw terminals 2.5 mm² - 16 mm² 2)
Certificates and compliance with standards ÖVE / ÖNORM E 8001-4-712, DIN V VDE 0126-1-1/A1, VDE AR N 4105, IEC 62109-1/-2, IEC 62116, IEC 61727, AS 3100, AS 4777-2, AS 4777-3, CER 06-190, G83/2, UNE 206007-1, SI 4777, CEI 0-21
EFFICIENCY 
Max. efficiency 98.0 %
MPP adaption efficiency > 99.9 %
PROTECTIVE DEVICES 
DC insulation measurement Yes
Overload behaviour Operating point shift, power limitation
DC disconnector Yes
INTERFACES 
WLAN / Ethernet LAN Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)
6 inputs and 4 digital inputs/outputs Interface to ripple control receiver
USB (type A socket) Datalogging, inverter update via USB flash drive
2 x RS422 (RJ45 socket) Fronius Solar Net, Interface protocol
Signalling output Energy management (floating relay output)
Datalogger and Webserver Included
External input S0 meter connection / Evaluation of overvoltage protection
RS4854) Modbus RTU SunSpec or meter connection

LiveZilla Live Chat Software